angiographic Romania

  • Triple-Rule-Out CT Angiography for Evaluation of Acute

     · To limit radiation to the patient, CT angiographic acquisition is monitored in real time and manually stopped as soon as the base of the heart is imaged. Note that setup specifies two reconstruction fields of view. Smaller (25-cm) field of view is used for evaluation of aorta and coronary anatomy. Larger field of view is used to evaluate

  • Peripheral Intervention ProductsAccess, Angiography

     · Merit VascularPeripheral. Merit’s peripheral intervention product portfolio offers solutions for Interventional Radiologists, including access and drainage products, angiography and intervention catheters, wires and snares, and a suite of embolotherapy products. We also support Renal Therapies with the Hero Graft family of products and

  • Comparison of fractional flow reserve and angiographic

    The aim of this study is to identify angiographic and functional mismatch using residual DS, dissection type and fractional flow reserve (FFR). Baseline and post-balloon parameters were obtained from 151 patients with 167 lesions. Angiographically significant parameters after balloon angioplasty are residual DS > 30% or dissection type C or more.

  • Long‐term clinical, angiographic, and optical coherence

     · Between December 2016 and December 2018, a total of 90 patients admitted for ACS and treated with MgBRS (Magmaris, Biotronik AG, Bülach, Switzerland) were enrolled in a multicenter prospective study. Clinical follow-up was performed in all patients at 24 months and angiographic and OCT follow-up in 51.5% of patients at 18 months.

  • Peripheral Intervention ProductsAccess, Angiography

     · Merit VascularPeripheral. Merit’s peripheral intervention product portfolio offers solutions for Interventional Radiologists, including access and drainage products, angiography and intervention catheters, wires and snares, and a suite of embolotherapy products. We also support Renal Therapies with the Hero Graft family of products and

  • Angiographic Surgical KitCoramed Medizinische

     · Angiographic Surgical Kit. februarie 27, 2013 by coramedmp. Content 1 surgical angiographic drape, 3-layers, 120 x 300 cm, with 2 adhesive holes ø 9 cm and transperent foil 70 cm on both sides 1 equipment cover, 120 x 120 cm , with elastic opening SibiuRomania Phone 0269/ 561 474

  • Radifocus® Angiographic Catheter

    Radifocus Angiographic Catheter is a 5 Fr angiographic catheter intended for use in angiographic procedures. It delivers radiopaque media and therapeutic agents to selected sites in the vascular system. It is also used to lead a guidewire or a catheter into the target site. . radifocus-glidecath-angiographic-catheter-product-image.

  • The Prognostic Value of Type D Personality in a Romanian

     · The Syntax angiographic score of severity had higher mean value in CHD patients with type D personality (t= 5.143 p < 0.001). Conclusions The presence of type D personality in CHD patients proved to be a reliable factor that indicated poor prognosis of disease.

  • Angiographic Catheter Radifocus Optitorque Catheter,

    An angiographic or diagnostic catheter is intended for use in angiographic procedures. It delivers radiopaque media and therapeutic agents to selected sites in the vascular system. It is also used to lead a guidewire or a catheter into the target site. Radifocus Optitorque, a full line of angiographic catheters designed for easy manipulation.

  • Can mean platelet volume truly predict credoweb.ro

     · CredoMedia Romania Pagin Impaired immediate angiographic reperfusion is a common complication in patients of ST-Elevation Myocardial Infarction (STEMI) treated by primary PCI, which carries an increased risk of further development of MACE. MPV-which is an indicator of platelet reactivity-may play an important role in occurrence of such

  • Angiographic management of percutaneous renal

     · The technical success rate in 64 patients with positive angiographic findings was 100%, and the clinical success rate in 70 patients who underwent transcatheter arterial embolization was 85.7% (60/70). A total of 14.3% (10/70) of patients with clinical failure underwent repeat transcatheter arterial embolization and all achieved clinical recovery.

  • CT Angiography of Pulmonary Embolism Diagnostic

     · A focal increase in vascular resistance can result from lung consolidation or atelectasis, is a cause of indeterminate CT pulmonary angiography, and can cause misdiagnosis of pulmonary embolism (,,,,,, Fig 35) (, 35 ). The unenhanced or poorly enhanced blood within the affected vessel may mimic pulmonary embolism.

  • Relationship between angiography timing and

     · Angiographic embolization is now considered the first-line therapy for acute gastrointestinal (GI) bleeding refractory to endoscopic therapy. The success of angiographic embolization depends on the detection of the bleeding site. This study aimed to identify the clinical and procedural predictors for the angiographic visualization of extravasation, including angiography timing, as well as

  • Anti‐Ro(SS‐A) autoantibodies in central nervous system

     · Objective To examine in Sjögren's syndrome (SS) the interrelationship between the presence of the anti-Ro(SS-A) antibody response and (1) concomitant presence and type (ie, focal or nonfocal) of CNS disease (CNS-SS), (2) cross-sectional brain MRI or CT, and (3) abnormal cerebral angiography. Methods Neurologic, neuroimaging, and angiographic features of CNS-SS patients were correlated

  • Global Angiographic Needles Market 2021 by

    The Angiographic Needles market report provides a detailed analysis of global market size, regional and country-level market size, segmentation market growth, market share, competitive Landscape, sales analysis, impact of domestic and global market players, value chain optimization, trade regulations, recent developments, opportunities analysis, strategic market growth analysis, product

  • Angiographic features of drug-induced bilateral angle

     · Background. Bilateral angle closure glaucoma with ciliochoroidal effusion and transient myopia is a well-known complication of sulfa drugs such as topiramate [1–3], hydrochlorothiazide [4–6], acetazolamide [6, 7], methazolamide [8, 9], and indapamide [].Recently, cases of bilateral angle closure glaucoma and transient myopia with ciliochoroidal effusion induced by mefenamic acid [] or

  • SiteSeer Coronary Diagnostic CatheterIndications

     · Cardiovascular angiographic catheters should only be used by or under the supervision of physicians trained in intravascular angiographic procedures. It is recommended that PTFE coated guide wires be used with cardiovascular angiographic catheters to enhance thromboresistance and lubricity.

  • Angiographic features of drug-induced bilateral angle

     · Angiographic features of drug-induced bilateral angle closure and transient myopia with Ciliochoroidal effusion Yong Koo Kang, Byeong Jae Son, Dong Ho Park and Jae Pil Shin* Abstract Background To report five cases of acute drug-induced angle closure and transient myopia with ciliochoroidal effusion and to analyze angiographic findings of

  • Peculiarities and Consequences of Different Angiographic

    Alexandru Burlacu, Grigore Tinica, Bogdan Artene, Paul Simion, Diana Savuc, Adrian Covic, " Peculiarities and Consequences of Different Angiographic Patterns of STEMI Patients Receiving Coronary Angiography Only Data from a Large Primary PCI Registry ", Emergency Medicine International, vol. 2020, Article ID , 7 pages, 2020. https //doi

  • Outlook™ Angiographic Catheter

    An angiographic or diagnostic catheter is intended for use in angiographic procedures. It delivers radiopaque media and therapeutic agents to selected sites in the vascular system. It is also used to lead a guidewire or a catheter to the target site. The Outlook 4 Fr (1.40 mm) has a large lumen to allow contrast media to be injected at high

  • Sizing Catheter Cook Medical

    Sizing Catheter. Intended for use in angiographic procedures by physicians trained and experienced in angiographic techniques. Standard techniques for placement of vascular access sheaths, angiographic catheters and wire guides should be employed. The products on

  • Optical coherence tomography angiographic findings of

     · Optical coherence tomography angiographic findings of lamellar macular hole comparisons between tractional and degenerative subtypes University of Ulsan College of Medicine, 88, Olympic-ro

  • Magnetic Resonance Angiography (MRA)

    magnetic resonance imaging (MRI) In magnetic resonance angiography (MRA), a powerful magnetic field, radio frequency waves and a computer are used to evaluate blood vessels and help identify abnormalities. This exam, like all MR-based exams, does not use radiation. An MRA exam may or may not use contrast material.

  • Relationship between angiography timing and

     · e success of angiographic embolization for acute GI bleeding depends on the detection of the bleeding artery site. Active contrast medium extravasation is the only direct and most common angiographic sign of acute GI bleeding, and can be treated with angiographic embo-lization [1211]. However, despite the established e, -

  • Angiography‐Based Machine Learning for Predicting

     · Between the ostium and 10 mm distal to the target lesion, a series of angiographic lumen diameter measurements along the centerline was plotted. The 24 computed angiographic features based on the diameter plot and 4 clinical features (age, sex, body surface area, and involve segment) were used for ML by XGBoost. The model was independently

  • ORIGINAL ARTICLE Clinical and angiographic predictors

    Romanian Journal of Cardiology Vol. 30, No. 2, 2020 231 Pavel Platon et al. Clinical and angiographic predictors in primary percutaneous intervention Variables Collected variables consisted of demographic data, clinical characteristics, pre-, post- and procedural an-giographic

  • Global Angiographic Entry Needles Market 2021 by

    The Angiographic Entry Needles market report provides a detailed analysis of global market size, regional and country-level market size, segmentation market growth, market share, competitive Landscape, sales analysis, impact of domestic and global market players, value chain optimization, trade regulations, recent developments, opportunities analysis, strategic market growth analysis, product

  • Atlas of CT AngiographyNormal and Pathologic Findings

    Gratian Dragoslav Miclaus, MD, PhD, is Head of the CT Department at the NEUROMED Diagnostic Imaging Center in Timisoara, Romania.He was the first doctor to perform CT angiography in Romania on a 64-slice CT scanner. Over the past 11 years he has gathered an impressive number of CT angiographic studies of the coronary arteries as well as of the brain vessels, pulmonary arteries, thoracic and